Stationary Constant Potential X-Ray Machine

Specificatii tehnice

  • Tube voltage:15~320KV, adjust constantly and the step is 1Kv
  • Tube current: 0~22.5mA, adjust constantly ,the step is 0.1mA
  • 320KV, 0~5mA (large focus), 0~2mA,
  • Cooling mode: oil, oil flow >22L/min
  • Exposure condition:
    • Tube voltage: 320KV
    • Tube current: 5mA
    • Double foil lead intensifying screen
    • Focus distance: 600mm
    • Exposure time: 10min
    • Developing temperature: 20 Industrial X-ray film
  • Max. Penetration (by Radiography): 75mm (A3 steel as reference)
  • Sensitivity: ≤ 1.5%
  • Film density: >1.5

Stationary Constant Potential X-Ray Machine- TTSCP

Stationary Constant Potential X-ray machine is an NDT equipment, which is used to control and adjust constant potential x-ray and it may detect the inside defection of workpiece via radiography.

This X-ray unit adopts the High Frequency technology which promises the high voltage supplied the X-ray tube inserted with high precision.  The High Frequency technology reduces the time of starting and closing for whole machine in order to improve work efficiency. At the same time, this technology reduces the weight and size of components of machine.

Technical Specifications:

Main Machine:

  • Tube voltage:15~320KV, adjust constantly and the step is 1Kv
  • Tube current: 0~22.5mA, adjust constantly ,the step is 0.1mA
  • 320KV, 0~5mA (large focus), 0~2mA,
  • Cooling mode: oil, oil flow >22L/min
  • Exposure condition:
    • Tube voltage: 320KV
    • Tube current: 5mA
    • Double foil lead intensifying screen
    • Focus distance: 600mm
    • Exposure time: 10min
    • Developing temperature: 20 Industrial X-ray film
  • Max. Penetration (by Radiography): 75mm (A3 steel as reference)
  • Sensitivity: ≤ 1.5%
  • Film density: >1.5

X-ray Tube Inserted:

  • Max. tube voltage:320kv
  • Continuous rating: 640W/1600W
  • Focal spot: d=1.9mm(small focus)/d=3.6 mm(large focus) (EN12543) or 0.8× 0.8(small focus) / 1.8 × 1.8 (acc. to IEC. 336)
  • Filament current:4.9A / 4.6A
  • Filament voltage, typical:3.0 V / 6.8V
  • Inherent filtration:3mm Be
  • Target material: W
  • Target angle:20°
  • Radiation coverage: 40°
  • Leakage radiation, max.:5mSv/h
  • Cooling medium: oil
  • Cooling medium flow, min.:14l/min
  • Temperature at inlet,max.:50℃
  • Weight:40kg
  • Terminal type:R24

High Voltage Cables

  • 160KV, length with 10m/Pc, adopt flange to connect

H160 Model High Frequency High Voltage Generator

  • Input Voltage:220VAC±10%
  • Frequency:50Hz±2%
  • Power:≥5KW
  • Output Voltage:15KV~320KV KV regulate precision:1KV
  • Current:20mA mA regulate precision:0.1mA
  • Mainframe frequency: 40KHz
  • Employment temperature:5~50℃
  • Employment humidity:≤80%
  • Insulated material: oil

Controller

  • 5.7 inch touch screen display
  • Siemens PLC controller
  • Screen displays the current working value by number and bar graph
  • Each function parameters inter-lock diagnostic result is showed by display screen
  • The controller makes alarm in sound and light signals due to high voltage variation
  • It also has the functions of safe interlock protection and alarm in case the conditions are not in accordance with exposure requirement or due to wrong operations
  • It has automatic warm-up and intellective training machine function, insure the vacuum degree of X-ray tube
  • Exposure time add up function

Oil Cooler

Oil Cooler has oil flow- rate relay protection switch and oil temperature protection switch inside. When oil flow rate <22L/min , flow- rate switch begins to work, and the x-ray equipment will enter into protection mode, the controller shows the error warning ; When oil temperature >40℃, x-ray equipment enter into protection mode, the controller shows the error warning. That means the oil cooling system will perform double strict protections to the X-ray tube.

X-ray Tube Support Device

This device adopts power-driven control, moves the X-ray tube up and down, horizontally and rotationally. Up-down lift distance is 500-1800mm. The user could choose the best state of the tested parts according to the test requirements.

Low Voltage Cable

It includes power cable, control cable, cooler cable, earthing wire, signal cable (commonly included lead door protection cable and warning lamp cable) etc.